Since the Fabry-Perot is classified as a ``private'' Palomar
instrument, the user must also disassemble and pack up the instrument
after using it. Because the Palomar crew begins their workday early,
i.e., 8:00 a.m., this usually means that the instrument must be
disassembled before going to bed after the last night of the run.
Fortunately, this task is much simpler than setting up the instrument;
it can be readily accomplished in about an hour. If for some reason
you are unable to disassemble the instrument before going to bed, you
should at least power down the etalon controller and remove the etalon
cables. Then contact the Palomar crew to notify them that you will be
returning later to pack up the instrument.
As expected, the tear-down procedure is essentially the setup
procedure in reverse order. To summarize the primary steps:
- 1.
- Run the fabry r command to release computer control of
the etalon controller. This will allow you to use the front-panel
controls on the CS-100 (see Figure 11).
- 2.
- Turn off the power to the CCD and the etalon controller. Be
sure to switch the operate/balance switch to balance first.
If you are at the 200-inch telescope, turn off the power to the
shutter controller as well. Close the valve on the nitrogen bottle,
and then the regulator itself.
- 3.
- Unplug all cables. This includes the CCD cables, the etalon
controller cables, and the nitrogen hose. If you are at the
200-inch telescope, the shutter cables and computer control coax
cables should also be removed, as well as the short-haul modems.
Pack all of the cables in the appropriate box.
- 4.
- If you are at the 200-inch telescope, pack up the shutter
controller and return the variable power supply to the electronics
lab.
- 5.
- Remove the CCD dewar from the instrument by loosening the
clamps on the dewar plate. Replace the lid on the chip side of the
dewar to protect the CCD window and place the dewar on a workbench.
The Palomar crew will take care of the CCD from this point.
- 6.
- Unbolt the instrument from the telescope. Following the setup
instructions in reverse, remove and pack the cable boot box, focus
plate, focus arm, camera lens, shutter (if used), and etalon. Take
care to replace the covers on the etalon and securely shut it within
its case. The extension ring must also be removed in order for the
instrument tube to fit in its case. Finally, replace the camera and
dewar plates on the tube, fasten the cardboard covers on either end
and over the cable boot hole, for protection, and pack the
instrument tube in its fiberglass case.
- 7.
- Pack up the etalon controller. If you are at the 200-inch
telescope, this will also involve removing the controller from the
Cassegrain rack and replacing it in its original cover.
- 8.
- Remove all filters from the filter wheel and restore them to
their original locations. If you are at the 200-inch telescope, be
sure to restore the filters to their original holders, and pack the
special filter holders with the Fabry-Perot equipment.
- 9.
- Pack up the calibration lamp. If you are at the 200-inch
telescope, you may have to wait until the Palomar crew can retrieve
the lamp from prime focus.
- 10.
- Remove the regulator from the nitrogen bottle, and pack it
with the Fabry-Perot equipment. Do not attempt to remove the
nitrogen bottle from the Cassegrain cage at the 200-inch telescope;
the Palomar crew will take care of this.
- 11.
- Tightly close all of the equipment cases. Check the telescope
to be sure that you have not forgotten any equipment.
If you are observing at the 60-inch telescope, you should store the
equipment cases in the ground-level storage room, across from the
elevator. If you are at the 200-inch telescope, stack the cases out
of the way on the observing floor; the Palomar crew will take them
back to the 60-inch storage room.
Be sure to retrieve the backup tapes of your data before departing the
mountain!